***Unit in good working condition*** Clinitek Atlas� Automated Urine Chemistry Analyzer (Carousel) Excellence in Automated Urinalysis - Productivity, Reliability, Flexibility, Ease-of-Use
A fully automated, bench top instrument designed for high-volume urine testing, using Siemens' proven technology in dry-pad urine chemistry analysis. Unique Reagent Format Simplifies Loading and Reduces Interruptions
* Continuous reagent roll offers high reliability of strip transport * Load 490 tests at 1 time for optimized reagent replacement time * Roll format minimizes reagent handling True Calibration of All Analytes Provides Confidence in Results
* Liquid ready-to use calibration material ensures accuracy * Minimizes lot variability
* Adjusts automatically to sample volume * Pour any volume ≥ 2 mL without need for special steps or tubes * Reduces time to prepare samples for testing
Adaptable to Laboratory Automation Systems
* Modular design facilitates track readiness
The Carousel Sample Handler Offers
* Sample loading options to meet testing and workflow needs. Loads trays with up to 50 samples or 40 samples plus calibrators and controls. * Trays available to accommodate different sample tube types. Clinitek Atlas With Carousel Sample Handler - General Dimensions Depth: 64.8 cm(25.5 in) Width: 72.4 cm(28.5 in) Height:66.0 cm(26.0 in) Weight (instrument base only) 59.0 kg(130lb.) Weight (sample handler only) 7.2 kg(15.8 lb.) Power Requirements 120 V 50/60 Hz, 100 V 50/60 Hz, 220-240 V 50/60 Hz Ambient Operating Temperature Rate 18°C to 30°C(64°F to 86° F) Ambient Operating Humidity Rate 20% to 80% relative humidity Compliance UL, CSA, CE Troughput 1 sample every 16 seconds Printer External
Sample Handling Trays Circular sample tray Tray Capacity 50 samples(can be used as 40 = position tray dedicated spaces for calibrators, controls, STATs) Sample Loading Capacity 1 tray up to 50 samples Sample Tubes Various depending on sample tray. Lipped tubes such as URIN-TEK or lipless up to 10.5 cm long Sample Volume Any volume from 2 mL to maximum fill of tube Pipette Precision impedance; ±1 µL accuracy Rinse Cycle Automatic pipette and SG well rinse between samples Stat Sample Handling Can be inserted during run; up to 2 samples Bar Codes Code 39, Interleaved 2 or 5, Codabar, Code 128
On-Board Computer Memory 1000 patient records plus 200 calibration control records Interfaces ASTM or mode to emulate Clinitek� 200+ Display 12 lines by 40 characters VGA display
Calibration Method Wet calibration with 1 or 2 point calibration for all reagents Frequency With every Reagent Pak change(or every 24 hours when multiple sample-lot Reagent Paks used within 24 hours)